Assist in sales of special material and methods of corrosion protection work

Hayashi-chemic is capable of appealing your products to Japan's leading companies directly through our PR activities.

We have been doing business with Japan's leading companies in every business sector (electric power companies, shipbuilding companies, chemical companies, oil refining companies, food companies, pharmaceutical companies, semiconductor manufacturers) for over 100 years.
In parallel with our sales division, which performs sales activities for mainly seal material, industrial equipment, etc, we have our construction division, which undertakes lining construction by ourselves to protect tanks from corrosion by hazardous fluids such as hydrochloric acid, sulfate, and so on. (For various construction work undertaken by us, please see below.)
For companies which haven’t established their sales routes to Japan’s leading companies despite of their having excellent material or methods for corrosion protection works or repair works, let us do PR activities for you. We are capable of appealing your products or methods to Japan’s major companies directly.
Please feel free to contact us so that we could assist you in expanding your sales.

When you have some trouble, what would you do?

(1) A rubber lined flange is cracked.

Solution

In such an event, hard rubber repair material "Balcon B" is used. Base treatment shall be carefully performed, then Balcon B be filled in. After curing, the surface of the flange shall be adjusted.

(2) FRP molded products is cracked!

Solution

In such an event, please leave it to Hayashi-chemic, it can be repaired by FRP lining.

(3) Flange of glass lined can is cracked!

Solution

In such an event, repair is possible by using Berzona ceramic R metal.

(4) Heavy oil piping is corroded on the outside, and heavy oil is leaking out. But fire must be kept out!

Solution

The leaking area shall be closed temporary in any cases. After applying Berzona ceramic R metal over the affected area, reinforce treatment shall be performed using special reinforcement tape.

(5) There is a hole in the corroded ceiling board in a dangerous material tank. But fire must be kept out!

Solution

In such an event, please leave it to Hayashi-chemic. We are capable of performing repair work using FRP plate.

(6) Concrete of a waste storage tank has been degraded and starts falling apart! Also it is leaking out!

Solution

In such an event, please leave it Hayashi-Chemic. We are capable of undertaking repair works by applying strong and thick lining using Polyurea resin.

(7) Water is leaking out from the concrete of an underground pit!

Solution

In such an event, please leave it to Hayashi-chemic. We are capable of undertaking repair works by stopping water leakage using urethane foam, the effect of which will last longer.